ASTM B338 Gr.1 Heat Exchanger Tubes Seamless Titanium Alloy Tubes For Condensers And Heat Exchangers
Contact Person : Richard SHEN
Phone Number : +86-13736164628
WhatsApp : +8613736164628
Minimum Order Quantity : | 10 Tons | Price : | USD1000-1300/ton |
---|---|---|---|
Packaging Details : | In wooden boxes or hexagonal bundles in seaworthy packing | Delivery Time : | 35-45days |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Place of Origin: | CHINA | Brand Name: | TORICH |
---|---|---|---|
Certification: | ISO9001, ISO14001, TS16949 | Model Number: | ASTM A226 |
Detail Information |
|||
Product Name: | ERW Carbon Steel Boiler Tube | Model No: | ASTM A226 |
---|---|---|---|
Technique: | ERW | Alloy Or Not: | Not Alloy |
Section Shape: | Round | Application: | For Boilers, Superheaters |
High Light: | Superheaters Carbon Steel Boiler Tubes,ASTM A226 Electric Resistance Welded Pipe,ERW Carbon Steel Boiler Tubes |
Product Description
Scope
1.1 This specification covers minimum-wall-thickness, electric-resistance-welded, carbon steel, boiler and superheater tubes for high-pressure service.
1.2 The tubing sizes and thicknesses usually furnished to this specification are 1/2 in. to 5 in. [12.7 to 127 mm] in outside diameter and 0.085 to 0.360 in. [2.2 to 9.1 mm] inclusive, in minimum wall thickness. Tubing having other dimensions may be furnished, provided such tubes comply with all other requirements of this specification.
1.3 Mechanical property requirements do not apply to tubing smaller than 1/8 in. [3.2 mm] in inside diameter or 0.015 in. [0.4 mm] in thickness.
1.4 When these products are to be used in applications conforming to ISO Recommendations for Boiler Construction, the requirements of Specification A520 shall supplement and supersede the requirements of this specification.
1.5 An optional supplementary requirement is provided and, when desired, shall be so stated in the order.
1.6 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. The inch-pound units shall apply unless the "M" designation of this specification is specified in the order.